READ AND SAVE THESE INSTRUCTIONSMODEL 8344 HEAT/COOL NON-PROGRAMMABLEMODEL 8346 HEAT PUMP NON-PROGRAMMABLEMODEL 8348 HEAT/COOL MULTI-STAGE NON-PROGRAM
CLEANING THE THERMOSTATIf the surface of the thermostat becomes dirty it can be cleaned with plainwater or a non-abrasive household cleaner including
3. Display will show only the room temperature and scale. Use the orbutton to toggle between Fahrenheit (F) or Celsius (C). 4. Press the LIGHT butto
1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature ADJUST buttons simultaneously (and ) until “ROOM” and “OFF” are n
5. Press the LIGHT button repeatedly until “DONE” is displayed. TO CHANGE THE WATER PANEL INDICATOR SETTINGThe Aprilaire Thermostat is capable of indi
3. Press the LIGHT button several times until “WATER PANEL” is displayedon the thermostat. 4. Use the or button to set this value to “1” if the home
TO SET NUMBER OF WEEKEND EVENTS (MODELS 8363, 8365 AND 8366 ONLY)Use this feature to set the number of events for the weekend program.The default valu
Your Research Products Corporation Aprilaire®Thermostat unit is expresslywarranted for two (2) years from date of installation to be free from defects
PRODUCT FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2GETTING FAMILIAR WITH YOUR APRILA
ENERGYSTAR®PROGRAM INFORMATION (Programmable Models Only)About half of all energy used by households goes to heating and cooling thehome. If you’ve se
3GETTING FAMILIAR WITH YOUR APRILAIRE THERMOSTATCURRENT TIME[Advance Time]PROGRAM[Advance Program]ADJUSTLIGHTFANMODEHOLDAuto•OnCool•Off•Heat•E-Heat[Re
OPERATING MODESYour thermostat has three operating modes, COOL, OFF and HEAT. Heat pumpModels 8346 & 8365 have an additional EMERGENCY HEAT mode (
ENERGYSTAR SETTINGSEvent TemperatureTime ScheduleSettingWeekday WeekendWake Heat = 70°F 6:00 AM 6:00 AMCool = 78°FLeave Heat = 62°F 8:00 AM 8:00 AMCoo
PROGRAM EVENTSYour thermostat has 5/2 (5 weekdays and 2 weekend days) programmingfunctionality, which allows the user to set four events for the weekd
TO CHANGE THE HEATING PROGRAMTO CHANGE THE COOLING PROGRAM1. Move the MODE switch to the COOL position. 2. Repeat the steps above to Program for cooli
BATTERY REPLACEMENTNOTE: New batteries must be replaced within one minute after removal ofold batteries. If more than one minute elapses the programme